3000 Series

3000 Specifications and Dimensions

 

Parameter

Value

Linear Range

0.190” 1.43 mm (45 mils) Linear range begins at 0.25 mm (10 mils) to 1.40 mm (55 mils)

0.300” 1.53 mm (60 mils) Linear range begins at 0.25 mm (10 mils) to 1.78 mm (70 mils)

Incremental Scale Factor (ISF)

 

7.87 V/mm (200 mV/mil) +/-10% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the linear range.

Deviation from best fit straight line (DSL)

15 ft. system length is less than ±0.05 mm (±2 mil). 20 ft. system length is less than ±0.076 mm (±3 mil).

Frequency response

0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring

Target Size

Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.)

Recommended perpendicular to shaft 75mm (3 in.)

Probe Tip Material

Polyphenylene sulfide (PPS).

Probe Cable Specifications

50 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable

Probe Case Material

AISI 303 or 304 stainless steel (SST).

Extension Cable Material

95 Ω coaxial, fluoroethylene propylene (FEP) insulated extension cable

System Length

15 ft or 20 ft.

Extension Cable Armor (optional)

Flexible AISI 302 SST with/without FEP outer jacket.

Tensile Strength (maximum rated)

220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor.

Connector material

Gold-plated brass

Recommended Connector Torque

Hand tightened

Maximum torque

0.56 N• m (5 in• lb)

Minimum bend Radius (with or without SS armor)

25.4 mm (1.0 in)

 

image-1660670380337.png

image-1660670397024.png

image-1660670417568.png

 

image-1660670425070.png