3300 Series
- 3300 5mm Specifications and Dimensions
- 3300 5mm Ordering
- 3300 8mm Specifications and Dimensions
- 3300 8mm Ordering
- 3300 11mm Specifications and Dimensions
- 3300 11mm Ordering
3300 5mm Specifications and Dimensions
Parameter |
Value |
Linear Range |
2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils). |
Incremental Scale Factor (ISF)
|
7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range |
Deviation from best fit straight line (DSL) |
1 to 5 meter system length is less than ±0.025 mm (±1 mil). 9 meter system length is less than ±0.038 mm (±1.5 mil). |
Frequency response |
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.
|
Target Size |
Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.) Recommended perpendicular to shaft 75mm (3 in.) |
Probe Tip Material |
Polyphenylene sulfide (PPS). |
Probe Case Material |
AISI 303 or 304 stainless steel (SST). |
Probe Cable Specifications |
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters |
Extension Cable Material |
75 Ω coaxial, fluoroethylene propylene (FEP) insulated |
System Length |
1 (probe only), 5 or 9 meters including extension cable |
Extension Cable Armor (optional) |
Flexible AISI 302 SST with/without FEP outer jacket |
Tensile Strength (maximum rated) |
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor |
Connector material |
Gold-plated brass |
Recommended Connector Torque |
Hand tightened |
Maximum torque |
0.56 N• m (5 in• lb) |
Minimum bend Radius (with or without SS armor) |
25.4 mm (1.0 in) |
Probe Temperature Range Operating Temperature |
-34°C to +177°C (-30°F to +350°F) |
Storage Temperature |
-51°C to +177°C (-60°F to +350°F) |
Extension Cable Operating and Storage Temperature |
-51°C to +177°C (-60°F to +350°F) |
Relative Humidity |
100% condensing, non-submersible when connectors are protected |
Imperial/US
Metric
Reverse Mount - Metric or Imperial
Extension Cables
Electrical
Linear Range:
2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils).
Incremental Scale Factor (ISF):
7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10
mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils)
linear range.
Deviation from best fit straight line (DSL):
1 to 5 meter system length is less than ±0.025 mm (±1 mil).
9 meter system length is less than ±0.038 mm (±1.5 mil).
Frequency response:
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.
Target Size:
Minimum flat: 25 mm (1.0 in) diameter.
Minimum perpendicular to shaft 50mm (2 in.).
Recommended perpendicular to shaft 75mm (3 in.).
Mechanical
Probe Tip Material:
Polyphenylene sulfide (PPS).
Probe Case Material:
AISI 303 or 304 stainless steel (SST).
Probe Cable Specifications:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters.
Extension Cable Material:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated.
System Length:
1 (probe only), 5 or 9 meters including extension cable
Extension Cable Armor (optional):
Flexible AISI 302 SST with/without FEP outer jacket.
Tensile Strength (maximum rated):
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor.
Connector material:
Gold-plated brass
Recommended Connector Torque:
Hand tightened
Maximum torque:
0.56 N• m (5 in• lb)
Minimum bend Radius (with or without SS armor):
25.4 mm (1.0 in)
Environmental Limits
Probe Temperature Range
Operating Temperature:
-34°C to +177°C (-30°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Extension Cable Temperature Range
Operating and Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Proximity Sensor Temperature Range
Operating Temperature:
-35°C to +177°C (-31°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Relative Humidity:
100% condensing, non-submersible when connectors are protected
3300 5mm Ordering
Imperial/US
Model | AA: Unthreaded Length | BB: Overall Case Length | CC: Total Length | DD: Connector & Cable Type | EE: Agency Approval |
MS330171-AA-BB-CC-DD-EE 1/4-28 UNF thread, no armor |
Order in increments of 0.5 in | Order in increments of 0.5 in |
05 = 0.5 meter/20 in |
01 = Miniature coaxial connector, connector protector & standard cable |
00 = Not Required |
MS330172-AA-BB-CC-DD-EE 1/4-28 UNF thread, with armor |
Example: 05 = 0.5 in | Example: 35 = 3.5 in |
10 = 1.0 meter/39 in |
02 = Miniature coaxial connector & standard cable |
05 = Multiple Approvals |
Minimum unthreaded length: 0.0 in | Minimum unthreaded length: 0.8 in |
50 = 5.0 meter/16.4 feet |
|||
Maximum unthreaded length: 9.9 in | Maximum unthreaded length: 9.9 in |
90 = 9.0 meter/29.5 feet |
Metric
Model | AA: Unthreaded Length | BB: Overall Case Length | CC: Total Length | DD: Connector & Cable Type | EE: Agency Approval |
MS330173-AA-BB-CC-DD-EE M8 x 1 thread, no armor |
Order in increments of 10 mm | Order in increments of 10 mm |
05 = 0.5 Meter/20 in |
01 = Miniature coaxial connector, connector protector & standard cable |
00 = Not Required |
MS330174-AA-BB-CC-DD-EE M8 x 1 thread, with armor |
Example: 06 = 60 mm | Example: 06 = 60 mm |
10 = 1.0 meter/39 in |
02 = Miniature coaxial connector & standard cable |
05 = Multiple Approvals |
Minimum unthreaded length: 0 mm | Minimum unthreaded length: 20 mm |
50 = 5.0 meter/16.4 feet |
|||
Maximum unthreaded length: 230 mm | Maximum unthreaded length: 250 mm |
90 = 9.0 meter/29.5 feet |
|
Reverse Mount
Model | AA: Total Length | BB: Connector & Cable Type | CC: Agency Approval |
MS330175-02-12-AA-BB-CC ⅜-24 UNF threads |
05 0.5 meter/20 in |
01 = Miniature coaxial connector, connector protector & standard cable | 00 = Not Required |
MS330176-05-30-AA-BB-CC M10 X 1 threads |
10 1.0 meter/39 in |
02 = Miniature coaxial connector & standard cable | 05 = Multiple Approvals |
50 5.0 meter/16.4 feet |
|||
90 9.0 meter/29.5 feet |
Extension Cable
Model | AA: Cable Length | BB: Connector & Cable Type | CC: Agency Approval |
MS330130 | 05 0.5 meter/20 in |
00 = No stainless steel armor. | 00 = Not Required |
10 1.0 meter/39 in |
01 = Stainless steel armor & FEP Jacket. | 05 = Multiple Approvals | |
50 5.0 meter/16.4 feet |
02 = Stainless steel armor, no FEP Jacket | ||
90 9.0 meter/29.5 feet |
3300 8mm Specifications and Dimensions
Parameter |
Value |
Linear Range |
2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41 mm (15 to 95 mils). |
Incremental Scale Factor (ISF)
|
7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range |
Deviation from best fit straight line (DSL) |
1 to 5 meter system length is less than ±0.025 mm (±1 mil). 9 meter system length is less than ±0.038 mm (±1.5 mil). |
Frequency response |
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.
|
Target Size |
Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.) Recommended perpendicular to shaft 75mm (3 in.) |
Probe Tip Material |
Polyphenylene sulfide (PPS). |
Probe Case Material |
AISI 303 or 304 stainless steel (SST). |
Probe Cable Specifications |
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters |
Extension Cable Material |
75 Ω coaxial, fluoroethylene propylene (FEP) insulated |
System Length |
1 (probe only), 5 or 9 meters including extension cable |
Extension Cable Armor (optional) |
Flexible AISI 302 SST with/without FEP outer jacket |
Tensile Strength (maximum rated) |
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor |
Connector material |
Gold-plated brass |
Recommended Connector Torque |
Hand tightened |
Maximum torque |
0.56 N• m (5 in• lb) |
Minimum bend Radius (with or without SS armor) |
25.4 mm (1.0 in) |
Probe Temperature Range Operating Temperature |
-34°C to +177°C (-30°F to +350°F) |
Storage Temperature |
-51°C to +177°C (-60°F to +350°F) |
Extension Cable Operating and Storage Temperature |
-51°C to +177°C (-60°F to +350°F) |
Relative Humidity |
100% condensing, non-submersible when connectors are protected |
Imperial/US

Metric
Reverse Mount - Metric or Imperial
Extension Cables
Electrical
Linear Range:
2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41
mm (15 to 95 mils).
Incremental Scale Factor (ISF):
7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10
mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils)
linear range.
Deviation from best fit straight line (DSL):
1 to 5 meter system length is less than ±0.025 mm (±1 mil).
9 meter system length is less than ±0.038 mm (±1.5 mil).
Frequency response:
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.
Target Size:
Minimum flat: 25 mm (1.0 in) diameter.
Minimum perpendicular to shaft 50mm (2 in.).
Recommended perpendicular to shaft 75mm (3 in.).
Mechanical
Probe Tip Material:
Polyphenylene sulfide (PPS).
Probe Case Material:
AISI 303 or 304 stainless steel (SST).
Probe Cable Specifications:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters.
Extension Cable Material:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated.
System Length:
1 (probe only), 5 or 9 meters including extension cable
Extension Cable Armor (optional):
Flexible AISI 302 SST with/without FEP outer jacket.
Tensile Strength (maximum rated):
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor.
Connector material:
Gold-plated brass
Recommended Connector Torque:
Hand tightened
Maximum torque:
0.56 N• m (5 in• lb)
Minimum bend Radius (with or without SS armor):
25.4 mm (1.0 in)
Environmental Limits
Probe Temperature Range
Operating Temperature:
-34°C to +177°C (-30°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Extension Cable Temperature Range
Operating and Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Proximity Sensor Temperature Range
Operating Temperature:
-35°C to +177°C (-31°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Relative Humidity:
100% condensing, non-submersible when connectors are protected
3300 8mm Ordering
Imperial/US
Model | AA: Unthreaded Length | BB: Overall Case Length | CC: Total Length | DD: Connector & Cable Type | EE: Agency Approval |
MS330101-AA-BB-CC-DD-EE 3/8-24 UNF thread, no armor |
Order in increments of 0.5 in | Order in increments of 0.5 in |
05 = 0.5 meter/20 in |
01 = Miniature coaxial connector, connector protector & standard cable |
00 = Not Required |
MS330102-AA-BB-CC-DD-EE 3/8-24 UNF thread, with armor |
Example: 05 = 0.5 in | Example: 35 = 3.5 in |
10 = 1.0 meter/39 in |
02 = Miniature coaxial connector & standard cable |
05 = Multiple Approvals |
Minimum unthreaded length: 0.0 in | Minimum unthreaded length: 0.8 in |
50 = 5.0 meter/16.4 feet |
|||
Maximum unthreaded length: 9.9 in | Maximum unthreaded length: 9.9 in |
90 = 9.0 meter/29.5 feet |
Metric
Model | AA: Unthreaded Length | BB: Overall Case Length | CC: Total Length | DD: Connector & Cable Type | EE: Agency Approval |
MS330103-AA-BB-CC-DD-EE M10 x 1 thread, no armor |
Order in increments of 10 mm | Order in increments of 10 mm |
05 = 0.5 Meter/20 in |
01 = Miniature coaxial connector, connector protector & standard cable |
00 = Not Required |
MS330104-AA-BB-CC-DD-EE M10 x 1 thread, with armor |
Example: 06 = 60 mm | Example: 06 = 60 mm |
10 = 1.0 meter/39 in |
02 = Miniature coaxial connector & standard cable |
05 = Multiple Approvals |
Minimum unthreaded length: 0 mm | Minimum unthreaded length: 20 mm |
50 = 5.0 meter/16.4 feet |
|||
Maximum unthreaded length: 230 mm | Maximum unthreaded length: 250 mm |
90 = 9.0 meter/29.5 feet |
|
Reverse Mount
Model | AA: Total Length | BB: Connector & Cable Type | CC: Agency Approval |
MS330105-02-12-AA-BB-CC ⅜-24 UNF threads |
05 0.5 meter/20 in |
01 = Miniature coaxial connector, connector protector & standard cable | 00 = Not Required |
MS330106-05-30-AA-BB-CC M10 X 1 threads |
10 1.0 meter/39 in |
02 = Miniature coaxial connector & standard cable | 05 = Multiple Approvals |
50 5.0 meter/16.4 feet |
|||
90 9.0 meter/29.5 feet |
Extension Cable
Model | AA: Cable Length | BB: Connector & Cable Type | CC: Agency Approval |
MS330130 | 05 0.5 meter/20 in |
00 = No stainless steel armor. | 00 = Not Required |
10 1.0 meter/39 in |
01 = Stainless steel armor & FEP Jacket. | 05 = Multiple Approvals | |
50 5.0 meter/16.4 feet |
02 = Stainless steel armor, no FEP Jacket | ||
90 9.0 meter/29.5 feet |
3300 11mm Specifications and Dimensions
Imperial
Metric
Extension Cables
Electrical
Linear Range:
4.0 mm (160 mils). Linear range begins at 0.50 mm (20 mils) from target and is from 0.50 to 4.50 mm (20 to 180 mils)
Incremental Scale Factor (ISF):
3.94 V/mm (100 mV/mil) +/-10% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.50 mm (20 mils) over the 4.0 mm (160 mils) linear range
Deviation from best fit straight line (DSL):
1 to 5 meter system length is less than ±0.10 mm (±4 mil).
9 meter system length is less than ±0.15 mm (±6 mil).
Frequency response:
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.
Target Size:
Minimum flat: 30.5 mm (1.2 in) diameter
Minimum perpendicular to shaft 150mm (6 in.)
Mechanical
Probe Tip Material:
Polyphenylene sulfide (PPS).
Probe Case Material:
AISI 303 or 304 stainless steel (SST).
Probe Cable Specifications:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters.
Extension Cable Material:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated.
System Length:
1 (probe only), 5 or 9 meters including extension cable
Extension Cable Armor (optional):
Flexible AISI 302 SST with/without FEP outer jacket.
Tensile Strength (maximum rated):
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor.
Connector material:
Gold-plated brass
Recommended Connector Torque:
Hand tightened
Maximum torque:
0.56 N• m (5 in• lb)
Minimum bend Radius (with or without SS armor):
25.4 mm (1.0 in)
Environmental Limits
Probe Temperature Range
Operating Temperature:
-34°C to +177°C (-30°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Extension Cable Temperature Range
Operating and Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Proximity Sensor Temperature Range
Operating Temperature:
-35°C to +177°C (-31°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Relative Humidity:
100% condensing, non-submersible when connectors are protected
3300 11mm Ordering
Imperial/US
Model | AA: Unthreaded Length | BB: Overall Case Length | CC: Total Length | DD: Connector & Cable Type | EE: Agency Approval |
MS330701-AA-BB-CC-DD-EE 1/2-20 UNF thread, no armor |
Order in increments of 0.5 in | Order in increments of 0.5 in |
05 = 0.5 meter/20 in |
01 = Miniature coaxial connector, connector protector & standard cable |
00 = Not Required |
MS330702-AA-BB-CC-DD-EE 1/2-20 UNF thread, with armor |
Example: 05 = 0.5 in | Example: 35 = 3.5 in |
10 = 1.0 meter/39 in |
02 = Miniature coaxial connector & standard cable |
05 = Multiple Approvals |
MS330707-AA-BB-CC-DD-EE 5/8-18 UNF thread, no armor |
Minimum unthreaded length: 0.0 in | Minimum unthreaded length: 0.8 in |
50 = 5.0 meter/16.4 feet |
||
MS330708-AA-BB-CC-DD-EE 5/8-18 UNF thread, with armor |
Maximum unthreaded length: 9.9 in | Maximum unthreaded length: 9.9 in |
90 = 9.0 meter/29.5 feet |
Metric
Model | AA: Unthreaded Length | BB: Overall Case Length | CC: Total Length | DD: Connector & Cable Type | EE: Agency Approval |
MS330703-AA-BB-CC-DD-EE M14 x 1.5 thread, no armor |
Order in increments of 10 mm | Order in increments of 10 mm |
05 = 0.5 Meter/20 in |
01 = Miniature coaxial connector, connector protector & standard cable |
00 = Not Required |
MS330704-AA-BB-CC-DD-EE M14 x 1.5 thread, with armor |
Example: 06 = 60 mm | Example: 06 = 60 mm |
10 = 1.0 meter/39 in |
02 = Miniature coaxial connector & standard cable |
05 = Multiple Approvals |
MS330709-AA-BB-CC-DD-EE M16 x 1.5 thread, no armor |
Minimum unthreaded length: 0 mm | Minimum unthreaded length: 20 mm |
50 = 5.0 meter/16.4 feet |
||
MS330710-AA-BB-CC-DD-EE M16 x 1.5 thread, no armor |
Maximum unthreaded length: 230 mm | Maximum unthreaded length: 250 mm |
90 = 9.0 meter/29.5 feet |
|
Reverse Mount
Model | AA: Total Length | BB: Connector & Cable Type | CC: Agency Approval |
MS330705-02-18-AA-BB-CC ⅜-24 UNF threads |
05 = 0.5 meter/20 in | 01 = Miniature coaxial connector, connector protector & standard cable | 00 = Not Required |
MS330706-05-46-AA-BB-CC M10 X 1 threads |
10 = 1.0 meter/39 in |
02 = Miniature coaxial connector & standard cable | 05 = Multiple Approvals |
50 = 5.0 meter/16.4 feet | |||
90 = 9.0 meter/29.5 feet |
Extension Cable
Model | AA: Cable Length | BB: Connector & Cable Type | CC: Agency Approval |
MS330730 | 05 0.5 meter/20 in |
00 = No stainless steel armor. | 00 = Not Required |
10 1.0 meter/39 in |
01 = Stainless steel armor & FEP Jacket. | 05 = Multiple Approvals | |
50 5.0 meter/16.4 feet |
02 = Stainless steel armor, no FEP Jacket | ||
90 9.0 meter/29.5 feet |