3300 Series

3300 5mm Specifications and Dimensions

 

Parameter

Value

Linear Range

2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils).

Incremental Scale Factor (ISF)

 

7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range

Deviation from best fit straight line (DSL)

1 to 5 meter system length is less than ±0.025 mm (±1 mil).

9 meter system length is less than ±0.038 mm (±1.5 mil).

Frequency response

0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.

 

Target Size

Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.)

Recommended perpendicular to shaft 75mm (3 in.)

Probe Tip Material

Polyphenylene sulfide (PPS).

Probe Case Material

AISI 303 or 304 stainless steel (SST).

Probe Cable Specifications

75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters

Extension Cable Material

75 Ω coaxial, fluoroethylene propylene (FEP) insulated

System Length

1 (probe only), 5 or 9 meters including extension cable

Extension Cable Armor (optional)

Flexible AISI 302 SST with/without FEP outer jacket

Tensile Strength (maximum rated)

220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor

Connector material

Gold-plated brass

Recommended Connector Torque

Hand tightened

Maximum torque

0.56 N• m (5 in• lb)

Minimum bend Radius (with or without SS armor)

25.4 mm (1.0 in)

Probe Temperature Range Operating Temperature

-34°C to +177°C (-30°F to +350°F)

Storage Temperature

-51°C to +177°C (-60°F to +350°F)

Extension Cable Operating and Storage Temperature

-51°C to +177°C (-60°F to +350°F)

Relative Humidity

100% condensing, non-submersible when connectors are protected

 

Imperial/USMS330171-MS330172.jpg

3301.png

Metric

MS330173-MS330174.jpg

 

3303.png

Reverse Mount - Metric or Imperial

MS330175-MS330176.jpg

3305.png

Extension Cables

image-1660669647875.png

image-1660669653709.png


Electrical

Linear Range:
2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils).
Incremental Scale Factor (ISF):
7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10
mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils)
linear range.
Deviation from best fit straight line (DSL):
1 to 5 meter system length is less than ±0.025 mm (±1 mil).
9 meter system length is less than ±0.038 mm (±1.5 mil).
Frequency response: 
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.
Target Size: 
Minimum flat: 25 mm (1.0 in) diameter.
Minimum perpendicular to shaft 50mm (2 in.).
Recommended perpendicular to shaft 75mm (3 in.).

Mechanical

Probe Tip Material:
Polyphenylene sulfide (PPS). 
Probe Case Material:
AISI 303 or 304 stainless steel (SST). 
Probe Cable Specifications:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. 
Extension Cable Material: 
75 Ω coaxial, fluoroethylene propylene (FEP) insulated. 
System Length:
1 (probe only),  5 or 9 meters including extension cable 
Extension Cable Armor (optional):
Flexible AISI 302 SST with/without FEP outer jacket. 
Tensile Strength (maximum rated):
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. 
Connector material:
Gold-plated brass
Recommended Connector Torque:
Hand tightened
Maximum torque:
0.56 N• m (5 in• lb)
Minimum bend Radius (with or without SS armor):
25.4 mm (1.0 in)

Environmental Limits

Probe Temperature Range

Operating Temperature:
-34°C to +177°C (-30°F to +350°F) 
Storage Temperature:
-51°C to +177°C (-60°F to +350°F) 

Extension Cable Temperature Range

Operating and Storage Temperature: 
-51°C to +177°C (-60°F to +350°F) 
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)

Proximity Sensor Temperature Range

Operating Temperature: 
-35°C to +177°C (-31°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Relative Humidity:
100% condensing, non-submersible when connectors are protected

 

3300 5mm Ordering

Imperial/US

Standard Option Descriptions
MS330XXX-AXX-BXX-CXX-DXX-EXX
Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval
MS330171-AA-BB-CC-DD-EE
1/4-28 UNF thread, no armor
Order in increments of 0.5 in Order in increments of 0.5 in

05 = 0.5 meter/20 in

01 = Miniature coaxial connector, connector protector & standard cable

00 = Not Required

MS330172-AA-BB-CC-DD-EE
1/4-28 UNF thread, with armor
Example: 05 = 0.5 in Example: 35 = 3.5 in

10 = 1.0 meter/39 in

02 = Miniature coaxial connector & standard cable

05 = Multiple Approvals
  Minimum unthreaded length: 0.0 in Minimum unthreaded length: 0.8 in

50 = 5.0

meter/16.4 feet

   
  Maximum unthreaded length: 9.9 in Maximum unthreaded length: 9.9 in

90 = 9.0 meter/29.5 feet

   

Metric

Metric Option Descriptions
MS330XXX-AXX-BXX-CXX-DXX-EXX
Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval
MS330173-AA-BB-CC-DD-EE
M8 x 1 thread, no armor
Order in increments of 10 mm Order in increments of 10 mm

05 = 0.5 Meter/20 in

01 = Miniature coaxial connector, connector protector & standard cable

00 = Not Required

MS330174-AA-BB-CC-DD-EE
M8 x 1 thread, with armor
Example: 06 = 60 mm Example: 06 = 60 mm

10 = 1.0 meter/39 in

02 = Miniature coaxial connector & standard cable

05 = Multiple Approvals
  Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm

50 = 5.0

meter/16.4 feet

   
  Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm

90 = 9.0

meter/29.5 feet

 

 

Reverse Mount

Model AA: Total Length BB: Connector & Cable Type CC: Agency Approval
MS330175-02-12-AA-BB-CC
⅜-24 UNF threads
05
0.5 meter/20 in
01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required
MS330176-05-30-AA-BB-CC
M10 X 1 threads
10
1.0 meter/39 in
02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals
  50
5.0 meter/16.4 feet
   
  90
9.0 meter/29.5 feet
   

Extension Cable

Model AA: Cable Length BB: Connector & Cable Type CC: Agency Approval
MS330130 05
0.5 meter/20 in
00 = No stainless steel  armor. 00 = Not Required
  10
1.0 meter/39 in
01 = Stainless steel armor & FEP Jacket. 05 = Multiple Approvals
  50
5.0 meter/16.4 feet
02 = Stainless steel armor, no FEP Jacket  
  90
9.0 meter/29.5 feet
   

3300 8mm Specifications and Dimensions

 

Parameter

Value

Linear Range

2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41 mm (15 to 95 mils).

Incremental Scale Factor (ISF)

 

7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range

Deviation from best fit straight line (DSL)

1 to 5 meter system length is less than ±0.025 mm (±1 mil).

9 meter system length is less than ±0.038 mm (±1.5 mil).

Frequency response

0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.

 

Target Size

Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.)

Recommended perpendicular to shaft 75mm (3 in.)

Probe Tip Material

Polyphenylene sulfide (PPS).

Probe Case Material

AISI 303 or 304 stainless steel (SST).

Probe Cable Specifications

75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters

Extension Cable Material

75 Ω coaxial, fluoroethylene propylene (FEP) insulated

System Length

1 (probe only), 5 or 9 meters including extension cable

Extension Cable Armor (optional)

Flexible AISI 302 SST with/without FEP outer jacket

Tensile Strength (maximum rated)

220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor

Connector material

Gold-plated brass

Recommended Connector Torque

Hand tightened

Maximum torque

0.56 N• m (5 in• lb)

Minimum bend Radius (with or without SS armor)

25.4 mm (1.0 in)

Probe Temperature Range Operating Temperature

-34°C to +177°C (-30°F to +350°F)

Storage Temperature

-51°C to +177°C (-60°F to +350°F)

Extension Cable Operating and Storage Temperature

-51°C to +177°C (-60°F to +350°F)

Relative Humidity

100% condensing, non-submersible when connectors are protected

 

Imperial/US
image-1660669434800.png

 

image-1660669471530.png

Metric

MS330703.png

image-1660669499837.png

Reverse Mount - Metric or Imperial

image-1660669510930.png

image-1660669526721.png

Extension Cables

image-1660669647875.png

image-1660669653709.png


Electrical

Linear Range:
2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41
mm (15 to 95 mils).
Incremental Scale Factor (ISF):
7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10
mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils)
linear range.
Deviation from best fit straight line (DSL):
1 to 5 meter system length is less than ±0.025 mm (±1 mil).
9 meter system length is less than ±0.038 mm (±1.5 mil).
Frequency response: 
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.
Target Size: 
Minimum flat: 25 mm (1.0 in) diameter.
Minimum perpendicular to shaft 50mm (2 in.).
Recommended perpendicular to shaft 75mm (3 in.).

Mechanical

Probe Tip Material:
Polyphenylene sulfide (PPS). 
Probe Case Material:
AISI 303 or 304 stainless steel (SST). 
Probe Cable Specifications:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. 
Extension Cable Material: 
75 Ω coaxial, fluoroethylene propylene (FEP) insulated. 
System Length:
1 (probe only),  5 or 9 meters including extension cable 
Extension Cable Armor (optional):
Flexible AISI 302 SST with/without FEP outer jacket. 
Tensile Strength (maximum rated):
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. 
Connector material:
Gold-plated brass
Recommended Connector Torque:
Hand tightened
Maximum torque:
0.56 N• m (5 in• lb)
Minimum bend Radius (with or without SS armor):
25.4 mm (1.0 in)

Environmental Limits

Probe Temperature Range

Operating Temperature:
-34°C to +177°C (-30°F to +350°F) 
Storage Temperature:
-51°C to +177°C (-60°F to +350°F) 

Extension Cable Temperature Range

Operating and Storage Temperature: 
-51°C to +177°C (-60°F to +350°F) 
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)

Proximity Sensor Temperature Range

Operating Temperature: 
-35°C to +177°C (-31°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Relative Humidity:
100% condensing, non-submersible when connectors are protected

 

3300 8mm Ordering

Imperial/US

Standard Option Descriptions
MS330XXX-AXX-BXX-CXX-DXX-EXX
Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval
MS330101-AA-BB-CC-DD-EE
3/8-24 UNF thread, no armor
Order in increments of 0.5 in Order in increments of 0.5 in

05 = 0.5 meter/20 in

01 = Miniature coaxial connector, connector protector & standard cable

00 = Not Required

MS330102-AA-BB-CC-DD-EE
3/8-24 UNF thread, with armor
Example: 05 = 0.5 in Example: 35 = 3.5 in

10 = 1.0 meter/39 in

02 = Miniature coaxial connector & standard cable

05 = Multiple Approvals
  Minimum unthreaded length: 0.0 in Minimum unthreaded length: 0.8 in

50 = 5.0

meter/16.4 feet

   
  Maximum unthreaded length: 9.9 in Maximum unthreaded length: 9.9 in

90 = 9.0 meter/29.5 feet

   

Metric

Metric Option Descriptions
MS330XXX-AXX-BXX-CXX-DXX-EXX
Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval
MS330103-AA-BB-CC-DD-EE
M10 x 1 thread, no armor
Order in increments of 10 mm Order in increments of 10 mm

05 = 0.5 Meter/20 in

01 = Miniature coaxial connector, connector protector & standard cable

00 = Not Required

MS330104-AA-BB-CC-DD-EE
M10 x 1 thread, with armor
Example: 06 = 60 mm Example: 06 = 60 mm

10 = 1.0 meter/39 in

02 = Miniature coaxial connector & standard cable

05 = Multiple Approvals
  Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm

50 = 5.0

meter/16.4 feet

   
  Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm

90 = 9.0

meter/29.5 feet

 

 

Reverse Mount

Model AA: Total Length BB: Connector & Cable Type CC: Agency Approval
MS330105-02-12-AA-BB-CC
⅜-24 UNF threads
05
0.5 meter/20 in
01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required
MS330106-05-30-AA-BB-CC
M10 X 1 threads
10
1.0 meter/39 in
02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals
  50
5.0 meter/16.4 feet
   
  90
9.0 meter/29.5 feet
   

Extension Cable

Model AA: Cable Length BB: Connector & Cable Type CC: Agency Approval
MS330130 05
0.5 meter/20 in
00 = No stainless steel  armor. 00 = Not Required
  10
1.0 meter/39 in
01 = Stainless steel armor & FEP Jacket. 05 = Multiple Approvals
  50
5.0 meter/16.4 feet
02 = Stainless steel armor, no FEP Jacket  
  90
9.0 meter/29.5 feet
   

3300 11mm Specifications and Dimensions

 

Imperial

MS330701-MS330702 v2.png

MS330707-MS330708 v2.png

Metric

MS330703-MS330704 v2.png

MS330709-MS330710 v2.png

Extension Cables

MS330730 v2.png


Electrical

Linear Range:
4.0 mm (160 mils). Linear range begins at 0.50 mm (20 mils) from target and is from 0.50 to 4.50 mm (20 to 180 mils) 
Incremental Scale Factor (ISF):
3.94 V/mm (100 mV/mil) +/-10% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.50 mm (20 mils) over the 4.0 mm (160 mils) linear range
Deviation from best fit straight line (DSL):
1 to 5 meter system length is less than ±0.10 mm (±4 mil). 
9 meter system length is less than ±0.15 mm (±6 mil). 
Frequency response: 
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. 
Target Size: 
Minimum flat: 30.5 mm (1.2 in) diameter
Minimum perpendicular to shaft 150mm (6 in.)

Mechanical

Probe Tip Material:
Polyphenylene sulfide (PPS). 
Probe Case Material:
AISI 303 or 304 stainless steel (SST). 
Probe Cable Specifications:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. 
Extension Cable Material: 
75 Ω coaxial, fluoroethylene propylene (FEP) insulated. 
System Length:
1 (probe only),  5 or 9 meters including extension cable 
Extension Cable Armor (optional):
Flexible AISI 302 SST with/without FEP outer jacket. 
Tensile Strength (maximum rated):
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. 
Connector material:
Gold-plated brass
Recommended Connector Torque:
Hand tightened
Maximum torque:
0.56 N• m (5 in• lb)
Minimum bend Radius (with or without SS armor):
25.4 mm (1.0 in)

Environmental Limits

Probe Temperature Range

Operating Temperature:
-34°C to +177°C (-30°F to +350°F) 
Storage Temperature:
-51°C to +177°C (-60°F to +350°F) 

Extension Cable Temperature Range

Operating and Storage Temperature: 
-51°C to +177°C (-60°F to +350°F) 
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)

Proximity Sensor Temperature Range

Operating Temperature: 
-35°C to +177°C (-31°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Relative Humidity:
100% condensing, non-submersible when connectors are protected

 

3300 11mm Ordering

Imperial/US

Standard Option Descriptions
MS330XXX-AXX-BXX-CXX-DXX-EXX
Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval
MS330701-AA-BB-CC-DD-EE
1/2-20 UNF thread, no armor
Order in increments of 0.5 in Order in increments of 0.5 in

05 = 0.5 meter/20 in

01 = Miniature coaxial connector, connector protector & standard cable

00 = Not Required

MS330702-AA-BB-CC-DD-EE
1/2-20 UNF thread, with armor
Example: 05 = 0.5 in Example: 35 = 3.5 in

10 = 1.0 meter/39 in

02 = Miniature coaxial connector & standard cable

05 = Multiple Approvals
MS330707-AA-BB-CC-DD-EE
5/8-18 UNF thread, no armor
Minimum unthreaded length: 0.0 in Minimum unthreaded length: 0.8 in

50 = 5.0

meter/16.4 feet

   
MS330708-AA-BB-CC-DD-EE
5/8-18 UNF thread, with armor
Maximum unthreaded length: 9.9 in Maximum unthreaded length: 9.9 in

90 = 9.0 meter/29.5 feet

   

Metric

Metric Option Descriptions
MS330XXX-AXX-BXX-CXX-DXX-EXX
Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval
MS330703-AA-BB-CC-DD-EE
M14 x 1.5 thread, no armor
Order in increments of 10 mm Order in increments of 10 mm

05 = 0.5 Meter/20 in

01 = Miniature coaxial connector, connector protector & standard cable

00 = Not Required

MS330704-AA-BB-CC-DD-EE
M14 x 1.5 thread, with armor
Example: 06 = 60 mm Example: 06 = 60 mm

10 = 1.0 meter/39 in

02 = Miniature coaxial connector & standard cable

05 = Multiple Approvals
MS330709-AA-BB-CC-DD-EE
M16 x 1.5 thread, no armor
Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm

50 = 5.0

meter/16.4 feet

   
MS330710-AA-BB-CC-DD-EE
M16 x 1.5 thread, no armor
Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm

90 = 9.0

meter/29.5 feet

 

 

Reverse Mount

Model AA: Total Length BB: Connector & Cable Type CC: Agency Approval
MS330705-02-18-AA-BB-CC
⅜-24 UNF threads
05 = 0.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required
MS330706-05-46-AA-BB-CC
M10 X 1 threads

10 = 1.0 meter/39 in

02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals
  50 = 5.0 meter/16.4 feet    
  90 = 9.0 meter/29.5 feet    

Extension Cable

Model AA: Cable Length BB: Connector & Cable Type CC: Agency Approval
MS330730 05
0.5 meter/20 in
00 = No stainless steel  armor. 00 = Not Required
  10
1.0 meter/39 in
01 = Stainless steel armor & FEP Jacket. 05 = Multiple Approvals
  50
5.0 meter/16.4 feet
02 = Stainless steel armor, no FEP Jacket  
  90
9.0 meter/29.5 feet