3300 Series 3300 5mm Specifications and Dimensions Parameter Value Linear Range 2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils). Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range Deviation from best fit straight line (DSL) 1 to 5 meter system length is less than ±0.025 mm (±1 mil). 9 meter system length is less than ±0.038 mm (±1.5 mil). Frequency response 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. Target Size Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.) Recommended perpendicular to shaft 75mm (3 in.) Probe Tip Material Polyphenylene sulfide (PPS). Probe Case Material AISI 303 or 304 stainless steel (SST). Probe Cable Specifications 75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters Extension Cable Material 75 Ω coaxial, fluoroethylene propylene (FEP) insulated System Length 1 (probe only), 5 or 9 meters including extension cable Extension Cable Armor (optional) Flexible AISI 302 SST with/without FEP outer jacket Tensile Strength (maximum rated) 220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor Connector material Gold-plated brass Recommended Connector Torque Hand tightened Maximum torque 0.56 N• m (5 in• lb) Minimum bend Radius (with or without SS armor) 25.4 mm (1.0 in) Probe Temperature Range Operating Temperature -34°C to +177°C (-30°F to +350°F) Storage Temperature -51°C to +177°C (-60°F to +350°F) Extension Cable Operating and Storage Temperature -51°C to +177°C (-60°F to +350°F) Relative Humidity 100% condensing, non-submersible when connectors are protected Imperial/US Metric Reverse Mount - Metric or Imperial Extension Cables Electrical Linear Range:2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils).Incremental Scale Factor (ISF):7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils)linear range.Deviation from best fit straight line (DSL):1 to 5 meter system length is less than ±0.025 mm (±1 mil).9 meter system length is less than ±0.038 mm (±1.5 mil).Frequency response: 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.Target Size: Minimum flat: 25 mm (1.0 in) diameter.Minimum perpendicular to shaft 50mm (2 in.).Recommended perpendicular to shaft 75mm (3 in.). Mechanical Probe Tip Material:Polyphenylene sulfide (PPS). Probe Case Material:AISI 303 or 304 stainless steel (SST). Probe Cable Specifications:75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. Extension Cable Material: 75 Ω coaxial, fluoroethylene propylene (FEP) insulated. System Length:1 (probe only),  5 or 9 meters including extension cable Extension Cable Armor (optional):Flexible AISI 302 SST with/without FEP outer jacket. Tensile Strength (maximum rated):220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. Connector material:Gold-plated brassRecommended Connector Torque:Hand tightenedMaximum torque:0.56 N• m (5 in• lb)Minimum bend Radius (with or without SS armor):25.4 mm (1.0 in) Environmental Limits Probe Temperature Range Operating Temperature:-34°C to +177°C (-30°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Extension Cable Temperature Range Operating and Storage Temperature: -51°C to +177°C (-60°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Proximity Sensor Temperature Range Operating Temperature: -35°C to +177°C (-31°F to +350°F)Storage Temperature:-51°C to +177°C (-60°F to +350°F)Relative Humidity:100% condensing, non-submersible when connectors are protected 3300 5mm Ordering Imperial/US Standard Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330171-AA-BB-CC-DD-EE1/4-28 UNF thread, no armor Order in increments of 0.5 in Order in increments of 0.5 in 05 = 0.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330172-AA-BB-CC-DD-EE1/4-28 UNF thread, with armor Example: 05 = 0.5 in Example: 35 = 3.5 in 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals Minimum unthreaded length: 0.0 in Minimum unthreaded length: 0.8 in 50 = 5.0 meter/16.4 feet Maximum unthreaded length: 9.9 in Maximum unthreaded length: 9.9 in 90 = 9.0 meter/29.5 feet Metric Metric Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330173-AA-BB-CC-DD-EEM8 x 1 thread, no armor Order in increments of 10 mm Order in increments of 10 mm 05 = 0.5 Meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330174-AA-BB-CC-DD-EEM8 x 1 thread, with armor Example: 06 = 60 mm Example: 06 = 60 mm 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm 50 = 5.0 meter/16.4 feet Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm 90 = 9.0 meter/29.5 feet Reverse Mount Model AA: Total Length BB: Connector & Cable Type CC: Agency Approval MS330175-02-12-AA-BB-CC⅜-24 UNF threads 050.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330176-05-30-AA-BB-CCM10 X 1 threads 101.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals 505.0 meter/16.4 feet 909.0 meter/29.5 feet Extension Cable Model AA: Cable Length BB: Connector & Cable Type CC: Agency Approval MS330130 050.5 meter/20 in 00 = No stainless steel  armor. 00 = Not Required 101.0 meter/39 in 01 = Stainless steel armor & FEP Jacket. 05 = Multiple Approvals 505.0 meter/16.4 feet 02 = Stainless steel armor, no FEP Jacket 909.0 meter/29.5 feet 3300 8mm Specifications and Dimensions Parameter Value Linear Range 2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41 mm (15 to 95 mils). Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range Deviation from best fit straight line (DSL) 1 to 5 meter system length is less than ±0.025 mm (±1 mil). 9 meter system length is less than ±0.038 mm (±1.5 mil). Frequency response 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. Target Size Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.) Recommended perpendicular to shaft 75mm (3 in.) Probe Tip Material Polyphenylene sulfide (PPS). Probe Case Material AISI 303 or 304 stainless steel (SST). Probe Cable Specifications 75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters Extension Cable Material 75 Ω coaxial, fluoroethylene propylene (FEP) insulated System Length 1 (probe only), 5 or 9 meters including extension cable Extension Cable Armor (optional) Flexible AISI 302 SST with/without FEP outer jacket Tensile Strength (maximum rated) 220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor Connector material Gold-plated brass Recommended Connector Torque Hand tightened Maximum torque 0.56 N• m (5 in• lb) Minimum bend Radius (with or without SS armor) 25.4 mm (1.0 in) Probe Temperature Range Operating Temperature -34°C to +177°C (-30°F to +350°F) Storage Temperature -51°C to +177°C (-60°F to +350°F) Extension Cable Operating and Storage Temperature -51°C to +177°C (-60°F to +350°F) Relative Humidity 100% condensing, non-submersible when connectors are protected Imperial/US Metric Reverse Mount - Metric or Imperial Extension Cables Electrical Linear Range:2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils).Incremental Scale Factor (ISF):7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils)linear range.Deviation from best fit straight line (DSL):1 to 5 meter system length is less than ±0.025 mm (±1 mil).9 meter system length is less than ±0.038 mm (±1.5 mil).Frequency response: 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.Target Size: Minimum flat: 25 mm (1.0 in) diameter.Minimum perpendicular to shaft 50mm (2 in.).Recommended perpendicular to shaft 75mm (3 in.). Mechanical Probe Tip Material:Polyphenylene sulfide (PPS). Probe Case Material:AISI 303 or 304 stainless steel (SST). Probe Cable Specifications:75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. Extension Cable Material: 75 Ω coaxial, fluoroethylene propylene (FEP) insulated. System Length:1 (probe only),  5 or 9 meters including extension cable Extension Cable Armor (optional):Flexible AISI 302 SST with/without FEP outer jacket. Tensile Strength (maximum rated):220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. Connector material:Gold-plated brassRecommended Connector Torque:Hand tightenedMaximum torque:0.56 N• m (5 in• lb)Minimum bend Radius (with or without SS armor):25.4 mm (1.0 in) Environmental Limits Probe Temperature Range Operating Temperature:-34°C to +177°C (-30°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Extension Cable Temperature Range Operating and Storage Temperature: -51°C to +177°C (-60°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Proximity Sensor Temperature Range Operating Temperature: -35°C to +177°C (-31°F to +350°F)Storage Temperature:-51°C to +177°C (-60°F to +350°F)Relative Humidity:100% condensing, non-submersible when connectors are protected 3300 8mm Ordering Imperial/US Standard Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330101-AA-BB-CC-DD-EE3/8-24 UNF thread, no armor Order in increments of 0.5 in Order in increments of 0.5 in 05 = 0.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330102-AA-BB-CC-DD-EE3/8-24 UNF thread, with armor Example: 05 = 0.5 in Example: 35 = 3.5 in 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals Minimum unthreaded length: 0.0 in Minimum unthreaded length: 0.8 in 50 = 5.0 meter/16.4 feet Maximum unthreaded length: 9.9 in Maximum unthreaded length: 9.9 in 90 = 9.0 meter/29.5 feet Metric Metric Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330103-AA-BB-CC-DD-EEM10 x 1 thread, no armor Order in increments of 10 mm Order in increments of 10 mm 05 = 0.5 Meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330104-AA-BB-CC-DD-EEM10 x 1 thread, with armor Example: 06 = 60 mm Example: 06 = 60 mm 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm 50 = 5.0 meter/16.4 feet Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm 90 = 9.0 meter/29.5 feet Reverse Mount Model AA: Total Length BB: Connector & Cable Type CC: Agency Approval MS330105-02-12-AA-BB-CC⅜-24 UNF threads 050.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330106-05-30-AA-BB-CCM10 X 1 threads 101.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals 505.0 meter/16.4 feet 909.0 meter/29.5 feet Extension Cable Model AA: Cable Length BB: Connector & Cable Type CC: Agency Approval MS330130 050.5 meter/20 in 00 = No stainless steel  armor. 00 = Not Required 101.0 meter/39 in 01 = Stainless steel armor & FEP Jacket. 05 = Multiple Approvals 505.0 meter/16.4 feet 02 = Stainless steel armor, no FEP Jacket 909.0 meter/29.5 feet 3300 11mm Specifications and Dimensions Imperial Metric Extension Cables Electrical Linear Range:4.0 mm (160 mils). Linear range begins at 0.50 mm (20 mils) from target and is from 0.50 to 4.50 mm (20 to 180 mils) Incremental Scale Factor (ISF):3.94 V/mm (100 mV/mil) +/-10% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.50 mm (20 mils) over the 4.0 mm (160 mils) linear range Deviation from best fit straight line (DSL):1 to 5 meter system length is less than ±0.10 mm (±4 mil). 9 meter system length is less than ±0.15 mm (±6 mil). Frequency response: 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. Target Size: Minimum flat: 30.5 mm (1.2 in) diameter Minimum perpendicular to shaft 150mm (6 in.) Mechanical Probe Tip Material:Polyphenylene sulfide (PPS). Probe Case Material:AISI 303 or 304 stainless steel (SST). Probe Cable Specifications:75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. Extension Cable Material: 75 Ω coaxial, fluoroethylene propylene (FEP) insulated. System Length:1 (probe only),  5 or 9 meters including extension cable Extension Cable Armor (optional):Flexible AISI 302 SST with/without FEP outer jacket. Tensile Strength (maximum rated):220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. Connector material:Gold-plated brassRecommended Connector Torque:Hand tightenedMaximum torque:0.56 N• m (5 in• lb)Minimum bend Radius (with or without SS armor):25.4 mm (1.0 in) Environmental Limits Probe Temperature Range Operating Temperature:-34°C to +177°C (-30°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Extension Cable Temperature Range Operating and Storage Temperature: -51°C to +177°C (-60°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Proximity Sensor Temperature Range Operating Temperature: -35°C to +177°C (-31°F to +350°F)Storage Temperature:-51°C to +177°C (-60°F to +350°F)Relative Humidity:100% condensing, non-submersible when connectors are protected 3300 11mm Ordering Imperial/US Standard Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330701-AA-BB-CC-DD-EE1/2-20 UNF thread, no armor Order in increments of 0.5 in Order in increments of 0.5 in 05 = 0.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330702-AA-BB-CC-DD-EE1/2-20 UNF thread, with armor Example: 05 = 0.5 in Example: 35 = 3.5 in 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals MS330707-AA-BB-CC-DD-EE5/8-18 UNF thread, no armor Minimum unthreaded length: 0.0 in Minimum unthreaded length: 0.8 in 50 = 5.0 meter/16.4 feet MS330708-AA-BB-CC-DD-EE5/8-18 UNF thread, with armor Maximum unthreaded length: 9.9 in Maximum unthreaded length: 9.9 in 90 = 9.0 meter/29.5 feet Metric Metric Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330703-AA-BB-CC-DD-EEM14 x 1.5 thread, no armor Order in increments of 10 mm Order in increments of 10 mm 05 = 0.5 Meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330704-AA-BB-CC-DD-EEM14 x 1.5 thread, with armor Example: 06 = 60 mm Example: 06 = 60 mm 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals MS330709-AA-BB-CC-DD-EEM16 x 1.5 thread, no armor Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm 50 = 5.0 meter/16.4 feet MS330710-AA-BB-CC-DD-EEM16 x 1.5 thread, no armor Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm 90 = 9.0 meter/29.5 feet Reverse Mount Model AA: Total Length BB: Connector & Cable Type CC: Agency Approval MS330705-02-18-AA-BB-CC⅜-24 UNF threads 05 = 0.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330706-05-46-AA-BB-CCM10 X 1 threads 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals 50 = 5.0 meter/16.4 feet 90 = 9.0 meter/29.5 feet Extension Cable Model AA: Cable Length BB: Connector & Cable Type CC: Agency Approval MS330730 050.5 meter/20 in 00 = No stainless steel  armor. 00 = Not Required 101.0 meter/39 in 01 = Stainless steel armor & FEP Jacket. 05 = Multiple Approvals 505.0 meter/16.4 feet 02 = Stainless steel armor, no FEP Jacket 909.0 meter/29.5 feet