Non-Contact Proximity Probes Non-Contact Proximity Probe System An industrial non-contact proximity probe typically consists of a coil, a mandrel, and a cable. Here's how these components are combined to make the probe: Coil: The coil is typically made of a fine wire wound around a former, which is usually made of a non-conductive material. The coil is a critical component of the probe, as it generates the electromagnetic field that interacts with the target object. Mandrel: The mandrel is a tubular structure that is typically made of a non-magnetic material, such as stainless steel or titanium. The coil is wound around the mandrel, which helps to keep it in place and maintain its shape. Cable: The cable is used to connect the probe to the driver and signal conditioning electronics, which are typically located outside the sensing environment. The cable is typically made of a shielded coaxial cable that is designed to minimize noise and interference. To assemble the probe, the coil is wound around the mandrel, which is then typically coated with a layer of insulating material to protect the coil from the environment. The cable is then attached to the coil, and the entire assembly is typically mounted on a support structure, such as a bracket or flange. When the probe is in operation, the electromagnetic field generated by the coil interacts with the target object, which induces eddy currents in the object. These eddy currents generate a secondary electromagnetic field that is detected by the coil, and the resulting signal is then transmitted through the cable to the driver and signal conditioning electronics for processing and analysis. An industrial non-contact proximity probe typically consists of the following components: Sensor Head: This is the part of the probe that detects changes in position and proximity of the target. It typically uses electromagnetic or capacitive sensing technology. Signal Processing Unit: This unit is responsible for processing the sensor signals and converting them into electrical signals that can be read by a monitoring system or control unit. Amplifier: The amplifier boosts the signal from the sensor head to improve its accuracy and reliability. Cable: This connects the sensor head to the signal processing unit and can be shielded to reduce electromagnetic interference. Mounting Hardware: This allows the probe to be securely attached to the machine or equipment being monitored. Power Supply: The probe requires a power source, which can be supplied by batteries or an external power supply. Output Display: This component displays the output of the probe, which can include the distance or position of the target. 3309 (Focus View) Series 3309 (Focus View) Specifications and Dimensions Specifications Parameter Value Linear Range 2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils). Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +12.5%/–20% including interchangeability error when measured in increments of 0.25 mm (10 mils) over the 1.5 mm (60 mils) linear range Deviation from best fit straight line (DSL) Less than ±0.06 mm (± 2.3 mils) Frequency response 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. Target Size Minimum: 8.9 mm (0.35 in) diameter Recommended minimum: 13mm (0.5 in) diameter Axial position measurements on shaft diameters smaller than 13mm (0.5 in) will generally result in a change in scale factor. Reducing the gap between the probe and target will help limit the change in scale factor. Shaft Diameter Minimum (standard X-Y probe configuration): 30 mm (1.2 in) Minimum (X-Y proximity probes offset axially by 23 mm (0.9 in)): 20 mm (0.8 in) Measurements on shaft diameters smaller than 30 mm (1.2 in) usually require close spacing of radial vibration or axial position transducers. This creates the potential for their electromagnetic emitted fields to interact with one another (cross-talk), resulting in erroneous readings. To prevent cross-talk, maintain minimum separation of m transducer tips of at least 25 mm (1.0 in) for axial position measurements or 23 mm (0.9 in) for radial vibration measurements Probe Tip Material Polyphenylene sulfide (PPS). Probe Cable Specifications 75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 7 meters. Extension Cable Material 75 Ω coaxial, fluoroethylene propylene (FEP) insulated. System Length 5 or 7 meters including extension cable Extension Cable Armor (optional) Flexible AISI 302 SST with/without FEP outer jacket Tensile Strength (maximum rated) 220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor Connector material Gold-plated brass Recommended Connector Torque Hand tightened Maximum torque 0.56 N• m (5 in• lb) Minimum bend Radius (with or without SS armor) 25.4 mm (1.0 in) Probe Temperature Range Operating Temperature -34°C to +177°C (-30°F to +351°F) Storage Temperature -51°C to +177°C (-60°F to +351°F) Extension Cable Operating and Storage Temperature -51°C to +177°C (-60°F to +351°F) Relative Humidity 100% condensing, non-submersible when connectors are protected Imperial/US Metric Reverse Mount - Metric or Imperial Extension Cables 3309 (Focus View) Ordering Imperial/US Standard Option DescriptionsMS3309XX-AXX-BXX-CXX-DXX-EXX Model A: Unthreaded Length B: Overall Case Length C: Total Length D: Connector & Cable Type E: Agency Approval MS330901 ¼-28 UNF thread, no armor Order in increments of 0.1 in Order in increments of 0.1 in 05 = 0.5 Meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330902 ¼-28 UNF thread, with armor Example: 05 = 0.5 in Example: 35 = 3.5 in 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals MS330908 ⅜-28 UNF thread, no armor Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm 50 = 5.0 meter/16.4 feet 11 = Miniature coaxial connector, connector protector & fluid block cable MS330909 ⅜-24 UNF thread, with armor Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm 70 = 7.0 meter/23.0 feet 12 Miniature coaxial connector & fluid block cable Metric Metric Option DescriptionsMS3309XX-AXX-BXX-CXX-DXX-EXX Model A: Unthreaded Length B: Overall Case Length C: Total Length D: Connector & Cable Type E: Agency Approval MS330903 M8 x 1 thread, no armor Order in increments of 10 mm Order in increments of 10 mm 05 = 0.5 Meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330904 M8 x 1 thread, with armor Example: 06 = 60 mm Example: 06 = 60 mm 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals MS330905 M10 x 1 thread, no armor Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm 50 = 5.0 meter/16.4 feet MS330910 M10 x 1 thread, with armor Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm 90 = 9.0 meter/29.5 feet Reverse Mount Option DescriptionsMS330906-02-12-CXX-DXX-EXXMS330907-05-30-CXX-DXX-EXX Model AA: Total Length BB: Connector & Cable Type CC: Agency Approval MS330906-02-12 ⅜-24 UNF threads 05 = 0.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330907-05-30 M10 x 1 threads 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals 50 = 5.0 meter/16.4 feet 90 = 9.0 meter/29.5 feet Extension Cable Extension Cable Option DescriptionsMS330930-AXXX-BXX-CXX Model AA: Cable Length BB: Connector & Cable Type CC: Agency Approval MS330930 040=4.0 meter/13.1 feet 00 = No stainless steel  armor. 00 = Not Required 045=4.5 meter/14.8 feet 01 = Stainless steel armor & FEP Jacket. 05 = Multiple Approvals 060=6.0 meter/19.7 feet 02 = Stainless steel armor, no FEP Jacket 065=6.5 meter/21.3 feet 080=8.0 meter/26.2 feet 085=8.5 meter/27.8 3300 Series 3300 5mm Specifications and Dimensions Parameter Value Linear Range 2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils). Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range Deviation from best fit straight line (DSL) 1 to 5 meter system length is less than ±0.025 mm (±1 mil). 9 meter system length is less than ±0.038 mm (±1.5 mil). Frequency response 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. Target Size Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.) Recommended perpendicular to shaft 75mm (3 in.) Probe Tip Material Polyphenylene sulfide (PPS). Probe Case Material AISI 303 or 304 stainless steel (SST). Probe Cable Specifications 75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters Extension Cable Material 75 Ω coaxial, fluoroethylene propylene (FEP) insulated System Length 1 (probe only), 5 or 9 meters including extension cable Extension Cable Armor (optional) Flexible AISI 302 SST with/without FEP outer jacket Tensile Strength (maximum rated) 220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor Connector material Gold-plated brass Recommended Connector Torque Hand tightened Maximum torque 0.56 N• m (5 in• lb) Minimum bend Radius (with or without SS armor) 25.4 mm (1.0 in) Probe Temperature Range Operating Temperature -34°C to +177°C (-30°F to +350°F) Storage Temperature -51°C to +177°C (-60°F to +350°F) Extension Cable Operating and Storage Temperature -51°C to +177°C (-60°F to +350°F) Relative Humidity 100% condensing, non-submersible when connectors are protected Imperial/US Metric Reverse Mount - Metric or Imperial Extension Cables Electrical Linear Range:2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils).Incremental Scale Factor (ISF):7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils)linear range.Deviation from best fit straight line (DSL):1 to 5 meter system length is less than ±0.025 mm (±1 mil).9 meter system length is less than ±0.038 mm (±1.5 mil).Frequency response: 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.Target Size: Minimum flat: 25 mm (1.0 in) diameter.Minimum perpendicular to shaft 50mm (2 in.).Recommended perpendicular to shaft 75mm (3 in.). Mechanical Probe Tip Material:Polyphenylene sulfide (PPS). Probe Case Material:AISI 303 or 304 stainless steel (SST). Probe Cable Specifications:75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. Extension Cable Material: 75 Ω coaxial, fluoroethylene propylene (FEP) insulated. System Length:1 (probe only),  5 or 9 meters including extension cable Extension Cable Armor (optional):Flexible AISI 302 SST with/without FEP outer jacket. Tensile Strength (maximum rated):220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. Connector material:Gold-plated brassRecommended Connector Torque:Hand tightenedMaximum torque:0.56 N• m (5 in• lb)Minimum bend Radius (with or without SS armor):25.4 mm (1.0 in) Environmental Limits Probe Temperature Range Operating Temperature:-34°C to +177°C (-30°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Extension Cable Temperature Range Operating and Storage Temperature: -51°C to +177°C (-60°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Proximity Sensor Temperature Range Operating Temperature: -35°C to +177°C (-31°F to +350°F)Storage Temperature:-51°C to +177°C (-60°F to +350°F)Relative Humidity:100% condensing, non-submersible when connectors are protected 3300 5mm Ordering Imperial/US Standard Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330171-AA-BB-CC-DD-EE1/4-28 UNF thread, no armor Order in increments of 0.5 in Order in increments of 0.5 in 05 = 0.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330172-AA-BB-CC-DD-EE1/4-28 UNF thread, with armor Example: 05 = 0.5 in Example: 35 = 3.5 in 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals Minimum unthreaded length: 0.0 in Minimum unthreaded length: 0.8 in 50 = 5.0 meter/16.4 feet Maximum unthreaded length: 9.9 in Maximum unthreaded length: 9.9 in 90 = 9.0 meter/29.5 feet Metric Metric Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330173-AA-BB-CC-DD-EEM8 x 1 thread, no armor Order in increments of 10 mm Order in increments of 10 mm 05 = 0.5 Meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330174-AA-BB-CC-DD-EEM8 x 1 thread, with armor Example: 06 = 60 mm Example: 06 = 60 mm 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm 50 = 5.0 meter/16.4 feet Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm 90 = 9.0 meter/29.5 feet Reverse Mount Model AA: Total Length BB: Connector & Cable Type CC: Agency Approval MS330175-02-12-AA-BB-CC⅜-24 UNF threads 050.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330176-05-30-AA-BB-CCM10 X 1 threads 101.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals 505.0 meter/16.4 feet 909.0 meter/29.5 feet Extension Cable Model AA: Cable Length BB: Connector & Cable Type CC: Agency Approval MS330130 050.5 meter/20 in 00 = No stainless steel  armor. 00 = Not Required 101.0 meter/39 in 01 = Stainless steel armor & FEP Jacket. 05 = Multiple Approvals 505.0 meter/16.4 feet 02 = Stainless steel armor, no FEP Jacket 909.0 meter/29.5 feet 3300 8mm Specifications and Dimensions Parameter Value Linear Range 2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41 mm (15 to 95 mils). Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range Deviation from best fit straight line (DSL) 1 to 5 meter system length is less than ±0.025 mm (±1 mil). 9 meter system length is less than ±0.038 mm (±1.5 mil). Frequency response 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. Target Size Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.) Recommended perpendicular to shaft 75mm (3 in.) Probe Tip Material Polyphenylene sulfide (PPS). Probe Case Material AISI 303 or 304 stainless steel (SST). Probe Cable Specifications 75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters Extension Cable Material 75 Ω coaxial, fluoroethylene propylene (FEP) insulated System Length 1 (probe only), 5 or 9 meters including extension cable Extension Cable Armor (optional) Flexible AISI 302 SST with/without FEP outer jacket Tensile Strength (maximum rated) 220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor Connector material Gold-plated brass Recommended Connector Torque Hand tightened Maximum torque 0.56 N• m (5 in• lb) Minimum bend Radius (with or without SS armor) 25.4 mm (1.0 in) Probe Temperature Range Operating Temperature -34°C to +177°C (-30°F to +350°F) Storage Temperature -51°C to +177°C (-60°F to +350°F) Extension Cable Operating and Storage Temperature -51°C to +177°C (-60°F to +350°F) Relative Humidity 100% condensing, non-submersible when connectors are protected Imperial/US Metric Reverse Mount - Metric or Imperial Extension Cables Electrical Linear Range:2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41mm (15 to 95 mils).Incremental Scale Factor (ISF):7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils)linear range.Deviation from best fit straight line (DSL):1 to 5 meter system length is less than ±0.025 mm (±1 mil).9 meter system length is less than ±0.038 mm (±1.5 mil).Frequency response: 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.Target Size: Minimum flat: 25 mm (1.0 in) diameter.Minimum perpendicular to shaft 50mm (2 in.).Recommended perpendicular to shaft 75mm (3 in.). Mechanical Probe Tip Material:Polyphenylene sulfide (PPS). Probe Case Material:AISI 303 or 304 stainless steel (SST). Probe Cable Specifications:75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. Extension Cable Material: 75 Ω coaxial, fluoroethylene propylene (FEP) insulated. System Length:1 (probe only),  5 or 9 meters including extension cable Extension Cable Armor (optional):Flexible AISI 302 SST with/without FEP outer jacket. Tensile Strength (maximum rated):220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. Connector material:Gold-plated brassRecommended Connector Torque:Hand tightenedMaximum torque:0.56 N• m (5 in• lb)Minimum bend Radius (with or without SS armor):25.4 mm (1.0 in) Environmental Limits Probe Temperature Range Operating Temperature:-34°C to +177°C (-30°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Extension Cable Temperature Range Operating and Storage Temperature: -51°C to +177°C (-60°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Proximity Sensor Temperature Range Operating Temperature: -35°C to +177°C (-31°F to +350°F)Storage Temperature:-51°C to +177°C (-60°F to +350°F)Relative Humidity:100% condensing, non-submersible when connectors are protected 3300 8mm Ordering Imperial/US Standard Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330101-AA-BB-CC-DD-EE3/8-24 UNF thread, no armor Order in increments of 0.5 in Order in increments of 0.5 in 05 = 0.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330102-AA-BB-CC-DD-EE3/8-24 UNF thread, with armor Example: 05 = 0.5 in Example: 35 = 3.5 in 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals Minimum unthreaded length: 0.0 in Minimum unthreaded length: 0.8 in 50 = 5.0 meter/16.4 feet Maximum unthreaded length: 9.9 in Maximum unthreaded length: 9.9 in 90 = 9.0 meter/29.5 feet Metric Metric Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330103-AA-BB-CC-DD-EEM10 x 1 thread, no armor Order in increments of 10 mm Order in increments of 10 mm 05 = 0.5 Meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330104-AA-BB-CC-DD-EEM10 x 1 thread, with armor Example: 06 = 60 mm Example: 06 = 60 mm 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm 50 = 5.0 meter/16.4 feet Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm 90 = 9.0 meter/29.5 feet Reverse Mount Model AA: Total Length BB: Connector & Cable Type CC: Agency Approval MS330105-02-12-AA-BB-CC⅜-24 UNF threads 050.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330106-05-30-AA-BB-CCM10 X 1 threads 101.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals 505.0 meter/16.4 feet 909.0 meter/29.5 feet Extension Cable Model AA: Cable Length BB: Connector & Cable Type CC: Agency Approval MS330130 050.5 meter/20 in 00 = No stainless steel  armor. 00 = Not Required 101.0 meter/39 in 01 = Stainless steel armor & FEP Jacket. 05 = Multiple Approvals 505.0 meter/16.4 feet 02 = Stainless steel armor, no FEP Jacket 909.0 meter/29.5 feet 3300 11mm Specifications and Dimensions Imperial Metric Extension Cables Electrical Linear Range:4.0 mm (160 mils). Linear range begins at 0.50 mm (20 mils) from target and is from 0.50 to 4.50 mm (20 to 180 mils) Incremental Scale Factor (ISF):3.94 V/mm (100 mV/mil) +/-10% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.50 mm (20 mils) over the 4.0 mm (160 mils) linear range Deviation from best fit straight line (DSL):1 to 5 meter system length is less than ±0.10 mm (±4 mil). 9 meter system length is less than ±0.15 mm (±6 mil). Frequency response: 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. Target Size: Minimum flat: 30.5 mm (1.2 in) diameter Minimum perpendicular to shaft 150mm (6 in.) Mechanical Probe Tip Material:Polyphenylene sulfide (PPS). Probe Case Material:AISI 303 or 304 stainless steel (SST). Probe Cable Specifications:75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. Extension Cable Material: 75 Ω coaxial, fluoroethylene propylene (FEP) insulated. System Length:1 (probe only),  5 or 9 meters including extension cable Extension Cable Armor (optional):Flexible AISI 302 SST with/without FEP outer jacket. Tensile Strength (maximum rated):220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. Connector material:Gold-plated brassRecommended Connector Torque:Hand tightenedMaximum torque:0.56 N• m (5 in• lb)Minimum bend Radius (with or without SS armor):25.4 mm (1.0 in) Environmental Limits Probe Temperature Range Operating Temperature:-34°C to +177°C (-30°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Extension Cable Temperature Range Operating and Storage Temperature: -51°C to +177°C (-60°F to +350°F) Storage Temperature:-51°C to +177°C (-60°F to +350°F) Proximity Sensor Temperature Range Operating Temperature: -35°C to +177°C (-31°F to +350°F)Storage Temperature:-51°C to +177°C (-60°F to +350°F)Relative Humidity:100% condensing, non-submersible when connectors are protected 3300 11mm Ordering Imperial/US Standard Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330701-AA-BB-CC-DD-EE1/2-20 UNF thread, no armor Order in increments of 0.5 in Order in increments of 0.5 in 05 = 0.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330702-AA-BB-CC-DD-EE1/2-20 UNF thread, with armor Example: 05 = 0.5 in Example: 35 = 3.5 in 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals MS330707-AA-BB-CC-DD-EE5/8-18 UNF thread, no armor Minimum unthreaded length: 0.0 in Minimum unthreaded length: 0.8 in 50 = 5.0 meter/16.4 feet MS330708-AA-BB-CC-DD-EE5/8-18 UNF thread, with armor Maximum unthreaded length: 9.9 in Maximum unthreaded length: 9.9 in 90 = 9.0 meter/29.5 feet Metric Metric Option DescriptionsMS330XXX-AXX-BXX-CXX-DXX-EXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type EE: Agency Approval MS330703-AA-BB-CC-DD-EEM14 x 1.5 thread, no armor Order in increments of 10 mm Order in increments of 10 mm 05 = 0.5 Meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330704-AA-BB-CC-DD-EEM14 x 1.5 thread, with armor Example: 06 = 60 mm Example: 06 = 60 mm 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals MS330709-AA-BB-CC-DD-EEM16 x 1.5 thread, no armor Minimum unthreaded length: 0 mm Minimum unthreaded length: 20 mm 50 = 5.0 meter/16.4 feet MS330710-AA-BB-CC-DD-EEM16 x 1.5 thread, no armor Maximum unthreaded length: 230 mm Maximum unthreaded length: 250 mm 90 = 9.0 meter/29.5 feet Reverse Mount Model AA: Total Length BB: Connector & Cable Type CC: Agency Approval MS330705-02-18-AA-BB-CC⅜-24 UNF threads 05 = 0.5 meter/20 in 01 = Miniature coaxial connector, connector protector & standard cable 00 = Not Required MS330706-05-46-AA-BB-CCM10 X 1 threads 10 = 1.0 meter/39 in 02 = Miniature coaxial connector & standard cable 05 = Multiple Approvals 50 = 5.0 meter/16.4 feet 90 = 9.0 meter/29.5 feet Extension Cable Model AA: Cable Length BB: Connector & Cable Type CC: Agency Approval MS330730 050.5 meter/20 in 00 = No stainless steel  armor. 00 = Not Required 101.0 meter/39 in 01 = Stainless steel armor & FEP Jacket. 05 = Multiple Approvals 505.0 meter/16.4 feet 02 = Stainless steel armor, no FEP Jacket 909.0 meter/29.5 feet 3000 Series 3000 Specifications and Dimensions Parameter Value Linear Range 0.190” 1.43 mm (45 mils) Linear range begins at 0.25 mm (10 mils) to 1.40 mm (55 mils) 0.300” 1.53 mm (60 mils) Linear range begins at 0.25 mm (10 mils) to 1.78 mm (70 mils) Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +/-10% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the linear range. Deviation from best fit straight line (DSL) 15 ft. system length is less than ±0.05 mm (±2 mil). 20 ft. system length is less than ±0.076 mm (±3 mil). Frequency response 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring Target Size Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.) Recommended perpendicular to shaft 75mm (3 in.) Probe Tip Material Polyphenylene sulfide (PPS). Probe Cable Specifications 50 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable Probe Case Material AISI 303 or 304 stainless steel (SST). Extension Cable Material 95 Ω coaxial, fluoroethylene propylene (FEP) insulated extension cable System Length 15 ft or 20 ft. Extension Cable Armor (optional) Flexible AISI 302 SST with/without FEP outer jacket. Tensile Strength (maximum rated) 220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. Connector material Gold-plated brass Recommended Connector Torque Hand tightened Maximum torque 0.56 N• m (5 in• lb) Minimum bend Radius (with or without SS armor) 25.4 mm (1.0 in) Electrical Linear Range:0.190” 1.43 mm (45 mils) Linear range begins at 0.25 mm (10 mils) to 1.40 mm (55 mils)0.300” 1.53 mm (60 mils) Linear range begins at 0.25 mm (10 mils) to 1.78 mm (70 mils)Incremental Scale Factor (ISF):7.87 V/mm (200 mV/mil) +/-10% error (including interchangeability error) when measured in 10mil increments when measured in increments of 0.25 mm (10 mils) over the linear range.Deviation from best fit straight line (DSL):15 ft. system length is less than ±0.05 mm (±2 mil).20 ft. system length is less than ±0.076 mm (±3 mil). Frequency response: 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.Target Size: Minimum flat: 25 mm (1.0 in) diameterMinimum perpendicular to shaft 50mm (2 in.)Recommended perpendicular to shaft 75mm (3 in.) Mechanical Probe Tip Material:Polyphenylene sulfide (PPS). Probe Case Material:AISI 303 or 304 stainless steel (SST). Probe Cable Specifications:50 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable.Extension Cable Material: 95 Ω coaxial, fluoroethylene propylene (FEP) insulated extension cable.System Length:15 ft or 20 ft. Extension Cable Armor (optional):Flexible AISI 302 SST with/without FEP outer jacket.Tensile Strength (maximum rated):220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. Connector material:Gold-plated brass.Recommended Connector Torque:Hand-tightened.Maximum torque: 0.56 N• m (5 in• lb).Minimum bend Radius (with or without SS armor):25.4 mm (1.0 in). Environmental Limits Probe Temperature Range Operating Temperature:-34°C to +125°C (-30°F to +257°F)Storage Temperature:-51°C to +125°C (-60°F to +257°F) Extension Cable Temperature Range Operating and Storage Temperature: -51°C to +125°C (-60°F to +257°F).Storage Temperature:-51°C to +125°C (-60°F to +257°F). Proximity Sensor Temperature Range Operating Temperature: -35°C to +125°C (-31°F to +257°F).Storage Temperature:-51°C to +125°C (-60°F to +257°F).Relative Humidity:100% condensing, non-submersible when connectors are protected. 3000 Ordering 3000 Series, 190 Probes Option DescriptionsMS190XX-AXX-BXX-CXX-DXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type MS19000¼-28 UNF thread, no armor English English Minimum: 066 in. 02with connector MS19001¼-28 UNF thread, with armor Standard: 00 (0.0 in.) Standard: 30 (3.0 in.) Maximum: 3636 in. MS19007M8x1, no armor Increment: 05 (0.5 in.) Increment: 05 (0.5 in.) Increment: of 6 in MS19008M8x1, with armor Minimum: 00 (0.0 in.) Minimum: 11 (1.1 in.) Maximum: 10 (1.0 in.) Maximum: 96 (9.6 in.) Metric Metric Standard: 00 (0 mm) Standard: 07 (70 mm) Increment: 01 (10 mm) Increment: 01 (10 mm) Minimum: 00 (0.0 mm) Minimum: 02 (20 mm) Maximum: 02 (20 mm) Maximum: 25 (250 mm) 3000 Series, 300 Probes Option DescriptionsMS300XX-AXX-BXX-CXX-DXX Model AA: Unthreaded Length BB: Overall Case Length CC: Total Length DD: Connector & Cable Type MS30000⅜-28 UNF thread, no armor English English Minimum: 066 in. 02with connector MS30001⅜-24 UNF thread, with armor Standard: 00 (0.0 in.) Standard: 30 (3.0 in.) Maximum: 3636 in. MS30011M10x1, no armor Increment: 05 (0.5 in.) Increment: 05 (0.5 in.) Increment: of 6 in MS30012M10x1, with armor Minimum: 00 (0.0 in.) Minimum: 11 (1.1 in.) Maximum: 10 (1.0 in.) Maximum: 96 (9.6 in.) Metric Metric Standard: 00 (0 mm) Standard: 07 (70 mm) Increment: 01 (10 mm) Increment: 01 (10 mm) Minimum: 00 (0.0 mm) Minimum: 02 (20 mm) Maximum: 02 (20 mm) Maximum: 25 (250 mm) Extension Cable Model AA: Cable Length MS2789-AXXX no armor 108 = 108 in / 9 ft MS4454-AXXX with armor 120 = 120 in / 10 ft 132 = 132 in / 11 ft 144 = 144 in / 12 ft 156 = 156 in / 13 ft 168 = 168 in / 14 ft 180 = 180 in / 15 ft 192 = 192 in / 16 ft 204 = 204 in / 17 ft 7200 Series 7200 Specifications and Dimensions Specifications Parameter Value Linear Range 2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41 mm (15 to 95 mils) Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +/-4% error when measured in 10 mil increments when calibrated as a system. Error is 9.5% including interchangeability error when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range Deviation from best fit straight line (DSL) Less than ±0.06 mm (± 2.3 mils). Frequency response 0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. Target Size Minimum: 24 mm (1.0 in) diameter. Probe Tip Material Polyphenylene sulfide (PPS). Probe Cable Specifications 75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters Probe Case Material AISI 304 stainless steel (SST) Extension Cable Material 75 Ω coaxial, fluoroethylene propylene (FEP) insulated. System Length 5 or 7 meters including extension cable Extension Cable Armor (optional) Flexible AISI 302 SST with/without FEP outer jacket. Tensile Strength (maximum rated) 220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor Connector material Gold-plated brass Recommended Connector Torque Hand tightened Maximum torque 0.56 N• m (5 in• lb) Minimum bend Radius (with or without SS armor) 25.4 mm (1.0 in) Probe Temperature Range Operating Temperature -34°C to +125°C (-30°F to +257°F) Storage Temperature -51°C to +125°C (-60°F to +257°F) Extension Cable Operating and Storage Temperature -51°C to +177°C (-60°F to +351°F) Relative Humidity 100% condensing, non-submersible when connectors are protected Imperial Metric Reverse Mount Extension Cables