Skip to main content

3300 11mm Specifications and Dimensions

 

Imperial

MS330701-MS330702 v2.png

MS330707-MS330708 v2.png

Metric

MS330703-MS330704 v2.png

MS330709-MS330710 v2.png

Extension Cables

MS330730 v2.png


Electrical

Linear Range:
4.0 mm (160 mils). Linear range begins at 0.50 mm (20 mils) from target and is from 0.50 to 4.50 mm (20 to 180 mils) 
Incremental Scale Factor (ISF):
3.94 V/mm (100 mV/mil) +/-10% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.50 mm (20 mils) over the 4.0 mm (160 mils) linear range
Deviation from best fit straight line (DSL):
1 to 5 meter system length is less than ±0.10 mm (±4 mil). 
9 meter system length is less than ±0.15 mm (±6 mil). 
Frequency response: 
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. 
Target Size: 
Minimum flat: 30.5 mm (1.2 in) diameter
Minimum perpendicular to shaft 150mm (6 in.)

Mechanical

Probe Tip Material:
Polyphenylene sulfide (PPS). 
Probe Case Material:
AISI 303 or 304 stainless steel (SST). 
Probe Cable Specifications:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. 
Extension Cable Material: 
75 Ω coaxial, fluoroethylene propylene (FEP) insulated. 
System Length:
1 (probe only),  5 or 9 meters including extension cable 
Extension Cable Armor (optional):
Flexible AISI 302 SST with/without FEP outer jacket. 
Tensile Strength (maximum rated):
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. 
Connector material:
Gold-plated brass
Recommended Connector Torque:
Hand tightened
Maximum torque:
0.56 N• m (5 in• lb)
Minimum bend Radius (with or without SS armor):
25.4 mm (1.0 in)

Environmental Limits

Probe Temperature Range

Operating Temperature:
-34°C to +177°C (-30°F to +350°F) 
Storage Temperature:
-51°C to +177°C (-60°F to +350°F) 

Extension Cable Temperature Range

Operating and Storage Temperature: 
-51°C to +177°C (-60°F to +350°F) 
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)

Proximity Sensor Temperature Range

Operating Temperature: 
-35°C to +177°C (-31°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Relative Humidity:
100% condensing, non-submersible when connectors are protected