7200 Specifications and Dimensions
Specifications
Parameter |
Value |
Linear Range |
2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41 mm (15 to 95 mils) |
Incremental Scale Factor (ISF)
|
7.87 V/mm (200 mV/mil) +/-4% error when measured in 10 mil increments when calibrated as a system. Error is 9.5% including interchangeability error when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range |
Deviation from best fit straight line (DSL) |
Less than ±0.06 mm (± 2.3 mils). |
Frequency response |
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring. |
Target Size |
Minimum: 24 mm (1.0 in) diameter. |
Probe Tip Material |
Polyphenylene sulfide (PPS). |
Probe Cable Specifications |
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters |
Probe Case Material |
AISI 304 stainless steel (SST) |
Extension Cable Material |
75 Ω coaxial, fluoroethylene propylene (FEP) insulated. |
System Length |
5 or 7 meters including extension cable |
Extension Cable Armor (optional) |
Flexible AISI 302 SST with/without FEP outer jacket. |
Tensile Strength (maximum rated) |
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor |
Connector material |
Gold-plated brass |
Recommended Connector Torque |
Hand tightened |
Maximum torque |
0.56 N• m (5 in• lb) |
Minimum bend Radius (with or without SS armor) |
25.4 mm (1.0 in) |
Probe Temperature Range Operating Temperature |
-34°C to +125°C (-30°F to +257°F) |
Storage Temperature |
-51°C to +125°C (-60°F to +257°F) |
Extension Cable Operating and Storage Temperature |
-51°C to +177°C (-60°F to +351°F) |
Relative Humidity |
100% condensing, non-submersible when connectors are protected |
Imperial
No Comments