Skip to main content

3300 8mm Specifications and Dimensions

 

Parameter

Value

Linear Range

2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41 mm (15 to 95 mils).

Incremental Scale Factor (ISF)

 

7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range

Deviation from best fit straight line (DSL)

1 to 5 meter system length is less than ±0.025 mm (±1 mil).

9 meter system length is less than ±0.038 mm (±1.5 mil).

Frequency response

0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.

 

Target Size

Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.)

Recommended perpendicular to shaft 75mm (3 in.)

Probe Tip Material

Polyphenylene sulfide (PPS).

Probe Case Material

AISI 303 or 304 stainless steel (SST).

Probe Cable Specifications

75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters

Extension Cable Material

75 Ω coaxial, fluoroethylene propylene (FEP) insulated

System Length

1 (probe only), 5 or 9 meters including extension cable

Extension Cable Armor (optional)

Flexible AISI 302 SST with/without FEP outer jacket

Tensile Strength (maximum rated)

220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor

Connector material

Gold-plated brass

Recommended Connector Torque

Hand tightened

Maximum torque

0.56 N• m (5 in• lb)

Minimum bend Radius (with or without SS armor)

25.4 mm (1.0 in)

Probe Temperature Range Operating Temperature

-34°C to +177°C (-30°F to +350°F)

Storage Temperature

-51°C to +177°C (-60°F to +350°F)

Extension Cable Operating and Storage Temperature

-51°C to +177°C (-60°F to +350°F)

Relative Humidity

100% condensing, non-submersible when connectors are protected

 

Imperial/US
image-1660669434800.png

 

image-1660669471530.png

Metric

MS330703.png

image-1660669499837.png

Reverse Mount - Metric or Imperial

image-1660669510930.png

image-1660669526721.png

Extension Cables

image-1660669647875.png

image-1660669653709.png


Electrical

Linear Range:
2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41
mm (15 to 95 mils).
Incremental Scale Factor (ISF):
7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10
mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils)
linear range.
Deviation from best fit straight line (DSL):
1 to 5 meter system length is less than ±0.025 mm (±1 mil).
9 meter system length is less than ±0.038 mm (±1.5 mil).
Frequency response: 
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.
Target Size: 
Minimum flat: 25 mm (1.0 in) diameter.
Minimum perpendicular to shaft 50mm (2 in.).
Recommended perpendicular to shaft 75mm (3 in.).

Mechanical

Probe Tip Material:
Polyphenylene sulfide (PPS). 
Probe Case Material:
AISI 303 or 304 stainless steel (SST). 
Probe Cable Specifications:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters. 
Extension Cable Material: 
75 Ω coaxial, fluoroethylene propylene (FEP) insulated. 
System Length:
1 (probe only),  5 or 9 meters including extension cable 
Extension Cable Armor (optional):
Flexible AISI 302 SST with/without FEP outer jacket. 
Tensile Strength (maximum rated):
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor. 
Connector material:
Gold-plated brass
Recommended Connector Torque:
Hand tightened
Maximum torque:
0.56 N• m (5 in• lb)
Minimum bend Radius (with or without SS armor):
25.4 mm (1.0 in)

Environmental Limits

Probe Temperature Range

Operating Temperature:
-34°C to +177°C (-30°F to +350°F) 
Storage Temperature:
-51°C to +177°C (-60°F to +350°F) 

Extension Cable Temperature Range

Operating and Storage Temperature: 
-51°C to +177°C (-60°F to +350°F) 
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)

Proximity Sensor Temperature Range

Operating Temperature: 
-35°C to +177°C (-31°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Relative Humidity:
100% condensing, non-submersible when connectors are protected