3300 8mm Specifications and Dimensions
Parameter |
Value |
Linear Range |
2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41 mm (15 to 95 mils). |
Incremental Scale Factor (ISF)
|
7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10 mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils) linear range |
Deviation from best fit straight line (DSL) |
1 to 5 meter system length is less than ±0.025 mm (±1 mil). 9 meter system length is less than ±0.038 mm (±1.5 mil). |
Frequency response |
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.
|
Target Size |
Minimum flat: 25 mm (1.0 in) diameter Minimum perpendicular to shaft 50mm (2 in.) Recommended perpendicular to shaft 75mm (3 in.) |
Probe Tip Material |
Polyphenylene sulfide (PPS). |
Probe Case Material |
AISI 303 or 304 stainless steel (SST). |
Probe Cable Specifications |
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters |
Extension Cable Material |
75 Ω coaxial, fluoroethylene propylene (FEP) insulated |
System Length |
1 (probe only), 5 or 9 meters including extension cable |
Extension Cable Armor (optional) |
Flexible AISI 302 SST with/without FEP outer jacket |
Tensile Strength (maximum rated) |
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor |
Connector material |
Gold-plated brass |
Recommended Connector Torque |
Hand tightened |
Maximum torque |
0.56 N• m (5 in• lb) |
Minimum bend Radius (with or without SS armor) |
25.4 mm (1.0 in) |
Probe Temperature Range Operating Temperature |
-34°C to +177°C (-30°F to +350°F) |
Storage Temperature |
-51°C to +177°C (-60°F to +350°F) |
Extension Cable Operating and Storage Temperature |
-51°C to +177°C (-60°F to +350°F) |
Relative Humidity |
100% condensing, non-submersible when connectors are protected |
Imperial/US
Metric
Reverse Mount - Metric or Imperial
Extension Cables
Electrical
Linear Range:
2.0 mm (80 mils). Linear range begins at 0.38 mm (15 mils) from target and is from 0.38 to 2.41
mm (15 to 95 mils).
Incremental Scale Factor (ISF):
7.87 V/mm (200 mV/mil) +/-6.5% error (including interchangeability error) when measured in 10
mil increments when measured in increments of 0.25 mm (10 mils) over the 2.0 mm (80 mils)
linear range.
Deviation from best fit straight line (DSL):
1 to 5 meter system length is less than ±0.025 mm (±1 mil).
9 meter system length is less than ±0.038 mm (±1.5 mil).
Frequency response:
0 to 10kHz (-3 dB) typical, with up to 100 meters (300 feet) of field wiring.
Target Size:
Minimum flat: 25 mm (1.0 in) diameter.
Minimum perpendicular to shaft 50mm (2 in.).
Recommended perpendicular to shaft 75mm (3 in.).
Mechanical
Probe Tip Material:
Polyphenylene sulfide (PPS).
Probe Case Material:
AISI 303 or 304 stainless steel (SST).
Probe Cable Specifications:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 5, or 9 meters.
Extension Cable Material:
75 Ω coaxial, fluoroethylene propylene (FEP) insulated.
System Length:
1 (probe only), 5 or 9 meters including extension cable
Extension Cable Armor (optional):
Flexible AISI 302 SST with/without FEP outer jacket.
Tensile Strength (maximum rated):
220 N (50 lb) probe case to probe lead. 220 N (50 lb) at probe lead to extension cable connectors. 220 N (50 lb) probe case to stainless steel armor.
Connector material:
Gold-plated brass
Recommended Connector Torque:
Hand tightened
Maximum torque:
0.56 N• m (5 in• lb)
Minimum bend Radius (with or without SS armor):
25.4 mm (1.0 in)
Environmental Limits
Probe Temperature Range
Operating Temperature:
-34°C to +177°C (-30°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Extension Cable Temperature Range
Operating and Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Proximity Sensor Temperature Range
Operating Temperature:
-35°C to +177°C (-31°F to +350°F)
Storage Temperature:
-51°C to +177°C (-60°F to +350°F)
Relative Humidity:
100% condensing, non-submersible when connectors are protected
No Comments